Cross arch and antero–posterior dimen-sional changes of impressions and stone casts at different storage times

Section: Research Paper
Published
Jan 31, 2003
Pages
74-81

Abstract

The aim of study is to evaluate the linear dimensional changes (cross arch, anteroposterior dimensions) of imp-ressions and die stone casts of two brands of addition silicone impression materials (Express and President) for special master model using twosteps (puttywash) tech-nique, at different storage times before pouring of impression, by using of three dimensional measuring machine and to compare between the accuracy of the two brands of impression materials.
The results indicated that a significant difference between the interabutment dist-ances of impression and die stone casts. The Express impression materials produce the most accurate results.
There is slightly increase in inter-abutment distances of stone casts. At one hour storage time there are the smallest dimensional changes of impressions and stone casts in relation to construction of completearch fixed partial denture.